+-------------------------------------------------------+ | 2U4N-F-NODE BMC Firmware Release History. | +-------------------------------------------------------+ | Project Name : 2U4N-F-NODE | | | | BMC Chipset : ASPEED 2400 | +-------------------------------------------------------+ ;-----------------------------------------------------------------------; BMC Project Path : 2U4N-F-NODE Firmware Version : 7.24.00 DRAM Init Code : 0.59 Firmware Changes : 01. [New] Request By: BMC leader Jeff Changes: Add Chinese web ui Test Proposal: In the web login interface, choose Chinese and enter web. All web ui string should show Chinese. 02. [New] Request By: BMC leader Jeff Changes: Add IANA code 49622(0x00C1D6) to Get Device ID and Get Channel Authentication Capabilities command. Verify By : BMC QT Test Proposal : 1. Verify Manufacturer ID of response data of "Get Device ID" command is 0x00C1D6. 2. Verify OEM ID of response data of "Get Channel Authentication Capabilities" command is 0x00C1D6. 03. [Fix] Report By : TSD Symptom : After update Java to 8u131, Java console and Java SOL cannot work. Root cause : Java 8u131 will no longer trust MD5-signed code. Solution : Update Java key algorithm to SHA256withRSA. Verify By : QT Test Proposal : Verify Java console and Java SOL can be running Java version 8. 04. [FIX] Report By : BMC Leader Jeff Symptom : IE browser need to retry download jnlp file. Root cause : The jnlp download size is not content size which will result mac+safari hang and IE retry again on jnlp download. Solution : Update buffer size from 2048 to 0. Verify By : QT Test Proposal: 1. IE browser don't display retry meassge. 05. [FIX] Report By : Jeff BMC Leader Symptom : WebUI display bmc version issue.. Root cause : Our BMC version string format should be: Major.Minor.Aux All of them are decimal, displayed as x.xx.xx, example: 1.03.04.i.e. with leading zero for Minor and Aux. but not for Major. Solution : Modify WebUI code. Verify By : QT Test Proposal : Verify BMC version format is x.xx.xx(Major.Minor.Aux) in web dashboard. 06. [Change] Report By : Jeff BMC Leader Changes : Change the delay of BAT sensor reading. Verify By : QT Test Proposal : 1. Stress BMC 24hr by cold reset command. 2. Battery sensor should not generate event log. 07. [FIX] Report By : BMC Leader Jeff Symptom : BMC hang. Root cause : Every BMC send message to Node Manager. Node Manager will timeout and stack a message in message queue. If message queue be filled with messages , BMC will hang. Solution : If Node Manager had timeout, clear message queue. Verify By : QT Test Proposal : 1. BMC can work after send command to NM get temperature data. Note 01. BMC Firmware image filename: 2U4N-F_L7.24.00.ima Engineer Name : Ansel Chen Release Date : 16:50:00 Wed 07-18-2017 ;-----------------------------------------------------------------------;